substructure, or other hidden hazard is encountered. The trenchless
          excavation operations shall proceed only after a risk assessment is completed
          in the field. Visual confirmation of the product installation relative to existing
          facilities is the preferred method of proper installation clearance verification.

          Horizontal Directional Drilling (HDD)
          •  Equipment set up
          •  Facility Locating and Equipment set back
          •  Drill pit/receiving pit
          •  Pilot Bore
          •  Back Reaming
          •  Recording – Data logging, manual maps, electronic, GPS

          Pipe Jacking & Micro Tunneling
          •  Equipment set up
          •  Facility Locating and Equipment set back
          •  Drill pit/receiving pit















































                       Canadian Common Ground Alliance